Description
Features
viola and viola TD
- Max. Test voltage 42.5 kVrms / 60 kVpeak
- Voltage shapes: VLF truesinus?, VLF rectangular wave voltage and DC voltage
- VLF truesinus? test technology enables loadindependent, reproducible sinusoidal high voltage
- Cable testing according to: DIN VDE 0276-620/621 (CENELEC HD 620/621), IEEE 400-2012, IEEE 400.2-2013, IEC 60060-3
- Cable sheath testing according to IEC 60502/ IEC 60229
- Voltage withstand test on electrical equipment according to IEEE 433
viola TD
- Dissipation factor testing of electrical equipment and medium-voltage cables up to 35 kV
- Highly precise dissipation factor measurement with precision of 1 x 10-4
- Detection of leakage currents using VSE box (option)
- Better overview of the cable condition with Full Monitored Withstand Test in combination with the PD-TaD 60
- Full MWT = VLF cable testing with parallel dissipation factor and partial discharge measurement
See page 2 for available methods and combinations of methods - Fully automated and individually programmable diagnostic sequences incl. evaluation General Information
- Data transfer via USB interface
- Management of test and measurement data with PC software
- Automatic discharge unit
- Optionally expandable
- viola: to a PD diagnostics system
- viola TD: to a PD and full MWT diagnostics system
Reviews